Baldor EM3313T 10 HP 3 Phase Super-E Electric Motor 1770 RPM 215T Frame 230-460V OPSB

Low stock: 4 available
SKU: EM3313T
Regular price $1,756.42

Call 402-261-9563 for special pricing

Due to manufacturer policy, up-to-date pricing may only be available by phone, call for the latest quote.

Made in USA
60-day returns No-hassle policy
US-based support Mon–Fri 8:30–4:30 CT
Same-day shipping Order by 1:30 PM CT
45+ years expertise Compressor specialists

The Baldor EM3313T is a 10 HP three-phase air compressor duty electric motor built to handle the high starting load and torque that air compressors demand. It can be wired to run in either direction (CW or CCW).

Replacing a compressor motor? Match the frame, shaft, and mounting to your existing motor — and if you change the RPM, resize the pulley or sheave to keep your compressor's CFM. Not sure it will fit your setup? Contact us with your old motor's nameplate and we'll confirm the right replacement before you buy.

Backed by a Baldor (ABB) NEMA Premium limited manufacturer's warranty — 36 months from installation or 42 months from date of manufacture, whichever comes first. We package every motor carefully so it arrives ready to install, and we stand behind every sale. Questions about fit or specs? Get in touch.

Recommended magnetic starters

A magnetic starter protects this motor from overload and lets a pressure switch turn it on and off. Choose the one that matches how you wire the motor.

Wiring at 230 V
10 HP 3 Phase Magnetic Starter NEMA 1 208-230V 28 - 38 Amp P35T Shihlin Electric 10 HP 3-phase 208-230 V · 28–38 A overload · P35T $114.95 View
Wiring at 460 V
WEG 10 HP 3 Phase Magnetic Starter NEMA 1 460-480V 11 - 17 Amp ESW-B18D39E-R32 WEG 10 HP 3-phase 460-480 V · 11–17 A overload · ESW-B18D39E-R32 $129.95 View

Overview

Horsepower 10.0 HP
Speed Full-load (nameplate) shaft speed. 1770 RPM
Frame NEMA frame size — sets the mounting bolt pattern, shaft height and shaft diameter. 215T
Voltage 230-460 V
Phase Three Phase
Enclosure Motor housing type, e.g. TEFC (Totally Enclosed Fan Cooled) or ODP (Open Drip Proof). OPSB
Mounting Foot Mount (Rigid Base)
Shaft diameter 1-3/8"
Country of origin Where this motor is manufactured, per the manufacturer / supplier documentation. United States

Electrical

Full load amps (low voltage) Rated running current on the low-voltage connection. 25.4 A
Full load amps (high voltage) Rated running current on the high-voltage connection. 12.7 A
Locked rotor amps Inrush current drawn at startup, before the motor begins to turn. 87.6 A
NEMA code letter NEMA locked-rotor kVA/HP code letter. H
Efficiency at full load 91.7%
Power factor Ratio of real to apparent power at full load. 81%

Performance & Torque

Rated torque Continuous torque produced at the rated speed and load. 29.7 ft-lb
Locked rotor torque Starting torque as a percentage of rated torque. 176%
Breakdown torque Maximum torque the motor can produce before it stalls, as a percentage of rated torque. 363%
Slip Percentage the loaded speed falls below synchronous speed. 1.8%
Service factor Permissible continuous overload multiplier, e.g. 1.15 = 15% over rated HP. 1.15
NEMA design NEMA design letter (A/B/C/D) describing the torque and starting-current profile. B

Mechanical & Construction

Frame material Steel
Bearing (drive end) 6307
Bearing (opposite drive end) 6206
Lubricant / grease Polyrex EM (-20F to +300F)
Overall length 17.5″

Dimensions

Overall height From the base feet to the top of the frame. 10.04″
Overall width Widest point, including the terminal (conduit) box. 12.65″
Frame body diameter 9.57″
Shaft diameter Finished diameter of the drive shaft. 1.375″
Shaft extension length Usable shaft length beyond the motor face. 3.38″
Shaft keyway (W × L) 0.31″ × 2.38″
Base length 8.0″
Base width 9.5″
Mounting holes Number of holes in the mounting feet. 6
Mounting hole diameter 1.38″
Mounting hole spacing (F-B × S-S) Foot bolt-hole spacing: front-to-back × side-to-side. 7.0″ × 8.5″
Lead hole diameter 1.38″
Grease fitting location Each End
Lifting lug configuration Each End

Ratings & Environment

Insulation class Winding insulation temperature rating (A/B/F/H). F
Duty cycle S1 / Continuous means the motor can run indefinitely at rated load. CONT
Ambient temperature Surrounding air temperature the rating is based on. 40°C
Rotation Reversible
Inverter rated Whether the windings are rated for variable-frequency-drive (VFD) operation. Yes
Agency approvals CURUSEEV, NEMA PREMIUM

Wiring & Identification

Leads / wire size 9 @ 14 AWG
Lead termination Flying Leads
Connection diagram 9-Lead, 3PH Dual Voltage (Low 2Y / High 1Y) — CD0005
Catalog number EM3313T
Product code 37F614Z710