Customer Service was great quick shipment time packaging very well. No damage will leave another review after I get it going. I haven’t hooked it up yet.
Eaton 20 HP 3 Phase Magnetic Starter NEMA 1 440-480V 24 - 40 Amp A27CGF40C040
Eaton 3 Phase DP Motor Starter A27CGF40C040
Magnetic starters are electromagnetically operated switches that provide a safe method for certain motors to be started under a large motor load. The overload relay inside the magnetic starters will prevent the supply voltage from energizing the motor if the starter detects a motor overload situation. It comes complete with Nema 1 Metallic Enclosure and Adjustable Overload Relay from 24 to 40 Amps. This Starter is specifically designed to be used with 20 HP, 3 Phase 440 – 480 Volt Electric Motors. Wiring and Installation Instructions included.
Features
• NEMA 1 General Purpose Enclosure Standard
• UL Recognized Components UL File #E-1491, Guide NLDX2
• CSA Certified Components File #LR353, Guide 380W-1.14 Class 3211 04
• Stake On Incoming Line For Auxiliary Components
• Class 10 Trip Class
• Trip Free Mechanism
• Shrouded or Finger Proof Terminals to Reduce Possibility of Electrical Shock
• Series: A27
• Phase: 3
• 20 Hp
• Number of Poles: 3
• Current Rating: 40 Amps
• Control Circuit Voltage: 440~480 VAC
• 24-40 Amps / Adjustable
• Enclosed: Yes
• NEMA: NEMA 1
• Approvals: UL;CSA;CE
• H x W x D: 7.38 in x 7.69 in x 11.5 in
Overview
| Brand | Eaton |
|---|---|
| Horsepower Maximum motor horsepower this starter is rated to control at the listed voltage and phase. | 20.0 HP |
| Phase | Three Phase |
| Voltage | 440-480 V |
| Frequency | 60 Hz |
| Overload adjustment range The overload relay’s adjustable trip-current band. Set the dial to roughly 115% of the motor’s full-load amps. | 24.0–40.0 A |
| Enclosure NEMA 1 = general-purpose indoor. NEMA 4X = washdown / outdoor, dust- and corrosion-resistant. | NEMA 1 |
| Country of origin Where this starter is manufactured, per the manufacturer / supplier documentation. | United States |
| Catalog / part number | A27CGF40C040 |
Contactor & Control
| Contactor type The magnetic contactor that switches power to the motor. | Eaton A27 (definite purpose) |
|---|---|
| Contactor rating | 40 A |
| Coil / control voltage The voltage that energizes the contactor coil — supplied by the pressure switch or control circuit. | 440-480 VAC |
| Control scheme The pilot devices wired in: e.g. Reset only, Start/Stop + Reset, or Hand-Off-Auto (HOA). | Non-reversing |
Overload Protection
| Overload relay type Bimetallic relays trip on a heater element sized to the motor current; ambient-compensated means the trip point is stable across temperature. | Bimetallic, ambient-compensated |
|---|---|
| Trip class How long the relay tolerates locked-rotor current before tripping. Class 10 = within 10 s, standard for compressors. | Class 10 |
Enclosure & Physical
| Enclosure material | Steel |
|---|---|
| Dimensions (H × W × D) Approximate enclosure size from the manufacturer catalog. | 13.27″ H × 7.64″ W × 6.67″ D |
| Weight | 10.6 lb |
| Terminals | Box lugs (posidrive setscrew) + quick-connect, shrouded finger-proof |
Ratings & Compliance
| Agency approvals | UL Recognized, CSA Certified |
|---|---|
| Application notes | Non-reversing 3-phase definite-purpose starter. Wiring and installation instructions included. For air-compressor use, control the starter with a pressure switch. |