WEG 1/3 HP 115V Single Phase Magnetic Starter Electric Motor Control NEMA4X
Brand new 1/3 Horsepower at 115V or 1 HP at 230V single-phase magnetic starter. This is a quality WEG starter with a built-in overload which is adjustable from 5.6-8 amps. The non-metallic type NEMA 4X enclosure housing has four 3/4" punch out holes for incoming and outgoing wires. Also included are three rubber surround gromets for the 3/4" holes to protect the wires if needed. The PESW magnetic starter is ideal to help protect motors and ensure smooth operation.
PROFESSIONAL INSTALLATION IS REQUIRED
Specifications:
• Dimensions 9" x 4.325" x 4.75" (L x W x H)
• 1/3 HP @ 115V, 1 HP @ 230V
• Single Phase
• Amp Rating: 9 Amps
• Overload Relay: 5.6-8A
• Coil Voltage: 208V, 240V
• Reset Push Button Only
If you are using this starter on an air compressor, you will also need a pressure switch to control the starter. In this application the pressure switch controls the on and off of the starter depending on the pressure setting of the pressure switch.
Due to this being an electrical item, there is no warranty after installation.
Overview
| Brand | WEG |
|---|---|
| Horsepower Maximum motor horsepower this starter is rated to control at the listed voltage and phase. | 0.33–1.0 HP |
| Phase | Single Phase |
| Voltage | 115-240 V |
| Frequency | 60 Hz |
| Overload adjustment range The overload relay’s adjustable trip-current band. Set the dial to roughly 115% of the motor’s full-load amps. | 5.6–8.0 A |
| Enclosure NEMA 1 = general-purpose indoor. NEMA 4X = washdown / outdoor, dust- and corrosion-resistant. | NEMA 4X |
| Country of origin Where this starter is manufactured, per the manufacturer / supplier documentation. | Mexico / Brazil |
| Catalog / part number | PESWS-B9V24EX-RM62 |
Contactor & Control
| Contactor type The magnetic contactor that switches power to the motor. | WEG CWB9 |
|---|---|
| Contactor rating | 9 A |
| Coil / control voltage The voltage that energizes the contactor coil — supplied by the pressure switch or control circuit. | 208-240 VAC |
| Control scheme The pilot devices wired in: e.g. Reset only, Start/Stop + Reset, or Hand-Off-Auto (HOA). | Reset only |
| Auxiliary contacts Spare isolated contacts for interlocks, run indication, or a low-oil switch. | 1 NO + 1 NC, electrically isolated |
Overload Protection
| Overload relay type Bimetallic relays trip on a heater element sized to the motor current; ambient-compensated means the trip point is stable across temperature. | Bimetallic, ambient-compensated |
|---|---|
| Trip class How long the relay tolerates locked-rotor current before tripping. Class 10 = within 10 s, standard for compressors. | Class 10 |
| Reset mode Manual reset requires pressing the button after a trip; automatic re-closes on cooldown. | Selectable manual / automatic |
| Phase-loss protection Trips the motor off if one supply phase is lost, preventing single-phasing damage. | Yes |
Enclosure & Physical
| Enclosure material | Non-metallic (thermoplastic) |
|---|---|
| Dimensions (H × W × D) Approximate enclosure size from the manufacturer catalog. | 9.0″ H × 4.325″ W × 4.75″ D |
Ratings & Compliance
| Agency approvals | UL508A listed, cULus certified |
|---|---|
| Ambient temperature range | -4°F to +140°F (-20°C to +60°C) |
| Application notes | Rated 1/3 HP at 115 V or 1 HP at 208–240 V. Factory pre-wired; for air-compressor use, control the starter with a pressure switch. |